5.5
S
IGNALS AND REMOTE CONTROL
Integrated
ON/OFF
Can-bus
5.5.1
RJ45 connector
Do not connect a network or a computer on the port.
The port is reserved for parallel operation which is not currently available.
5.5.2
CAN-Bus connector
A CAN-bus is provided to monitor and control the device. Pure sine wave inverter offers two receptacles
matching with connectors Molex Microfit 3.0, 6 circuits (reference 43025-0600).
Application note n° 1728705REG_CAN (hardware and software specification) is available upon request.
5.5.3
ON/OFF remote option
External remote ON/OFF control is available as option (reference KERS-ON-OFF). It ensures a 0 Amp
consumption on your battery bank by switching Off the unit. First disconnect the jumper inside the unit and
connect the cable (straight-through cable) into the three-pole inlet.
Rj45
External remote ON/OFF (option ref: KERS-ON-OFF)
P 10