10. Disposal

For environmental reasons, do not dispose of the device in the household waste at the end of its useful
life. Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accord-
ance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions,
please contact the local authorities responsible for waste disposal.

11. What if there are problems?

Problem
Possible cause
Device does not
On/off button switched off
light up
No electricity
No electricity
The fluorescent tube is not correctly inserted
Fluorescent tube has reached the end of its
service life. Fluorescent tube is defective.

12. Technical specifications

Dimensions (WHD)
Weight
Lighting elements
Power
Light intensity
Radiation
Mains connection
Operating conditions
Storage conditions
Transport conditions
Product classification
Degree of efficiency of the ballast
Source effiency (lm/W) of the bulb
Color temperature of tubes
Subject to technical modifications.
This device meets the requirements of the European Directive 93/42/EEC and 2007/47/EEC Medical Devices as
well as the Medical Devices Act.
This device complies with European Standard EN60601-1-2 and is subject to particular precautions with regard
to electromagnetic compatibility. Please note that portable and mobile HF communication systems may interfere
with this unit. More details can be requested from the stated customer service address or found at the end of the
instructions for use.
270 x 207 x 80 mm
800 g
MP 45 3U 45W tubes, Daylight
45 watts
10,000 lux (15 cm)
Output of radiation beyond the visible spectrum (infrared and UV) is
so low that it is harmless to eyes and skin.
220-240 V ~, 50 Hz
+10°C to +25°C, < 30-90% relative humidity,
700-1060 hPa ambient pressure
-20°C to +50°C, relative humidity < 90%,
700-1060 hPa ambient pressure
-20°C to +50°C, relative humidity < 90%,
700-1060 hPa ambient pressure
Protection class II, IPX0, no AP or APG, continuous operation,
no ancillary parts
~ 96%
67–71 lm/W
6.500 Kelvin
12
Solution
Switch on the on/off button.
Connect the mains plug correctly.
The mains cable is defective. Contact
customer services or your retailer.
Insert the fluorescent tube correctly. (For
a description, see the Quick guide "Re-
placing the fluorescent tube")
Replace the fluorescent tube.
(For a description, see the Quick guide
"Replacing the fluorescent tube")