DRY AGER CARE
MAINTENANCE
Replacing the UV Lamp
1. Carefully loosen screws to UV Lamp
Cover to access the UV lamp.
2. To remove the UV lamp. Hold the UV
lamp firmly and turn it at a 45° angle
and pull old lamp out.
3. Install new UV lamp. Gently place
new lamp in place, firmly turning 45°
in opposite direction of removal. Place
UV lamp cover and tighten screws.
3
Moving the Appliance
• If you need to move your dry ager, turn off the appliance first. Remove all content.
Tape down all loose items inside your appliance. Tape doors shut. Be sure the
device stays in the upright position during transportation.
16
Pro Smoker®: Owner's Manual - Reserve 300 Dry Ager
1
2
TROUBLESHOOTING
Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment. Improperly performed repairs can cause
considerable dangers for the user and damages to the device.
Problem
Possible Cause
Appliance is not
External environment
getting cold enough
may require a lower
temperature setting
The door is being opened
too often, the door is not
closed completely, or the
door seal is damaged.
The applicance does not
have enough clearance.
Appliance needs to be
defrosted.
Vibrations coming
Appliance is unlevel, fan
from applicance &
is damaged or components
door is not closing.
are loose. Dry ager is
touching the the wall or the
door is reversed and not
properly installed.
The seal is weak or the
shelves are out of position.
The display does
Error with controller.
not work and/or the
buttons are not
functional.
© 2023 Pro Smoker
pro-smoker.com - Phone:
WARNING
Solution(s)
Set your temperature colder
Check the door to make sure
it's closed properly. Check
the seal for damage. If
damaged, replace the seal.
Ensure there is a minimum
6" clearance surrounding the
cabinet.
Defrost the appliance.
See instructions on pg 15.
Check for any of the described
issues and make any neces-
sary repairs.
Replace seal if damaged or
reposition shelving.
Unplug appliance, wait 2
minutes, plug in the appliance
again. If this does not solve the
problem, then please contact
customer service.
1-800-874-1949
17

Publicité