Location of Controls
(Side View)
*— POWER —,
GND
BATT
CONT
For used in stereo:
@): Left Side
(+)
: Left Side
(©)
© : Right Side (-)
O) : Right Side (+)
Otherwise the amplifier will not work.
O Bass Level Adjust Volume
Used for adjusting the bass output level.
O Filter Selector Switch
Used to activate the low-pass filter.
© Filter Frequency Adjust Volume
Used to change the cutoff frequency of the low-
pass filter within the range of 40 to 400 Hz
(when the filter selector switch is on).
© Level Adjust Volume
Used for adjusting the amplifier output level.
© Input Connector (RCA Terminal)
For connection with the cassette/CD player's
output.
CY-M7052EUC
LOW-PASS
FILTER
- =~
POWER
Side View (Input side)
Side View (Output side)
For used in monaural (bridgeable):
®) : (-)
©): (+)
O Fuse (20A)
This fuse is for circuit protection.
@ Power Supply Terminal
For connection with the power supply.
© Power Indicator and protect Indicator
Lights up when the power of the cassette/CD
player connected to this unit is switched on.
Lights up in red when protect circuit is activated,
and lights up in green when protect circuit is in-
active.
© Speaker Output Terminal
For connection with the speakers.