A
A. Rigid copper pipe or flexible pipe of
stainless steel
If the pilot lights turn on after connecting
the hob to the mains, turn on and off the
control knob and wait until the residual
heat indicator goes out.
3.6 Connection cable
To replace the connection cable use only the
special cable or its equivalent. The cable type
is: H03V2V2-F T90.
Make sure that the cable section is applicable
to the voltage and the working temperature.
The yellow / green earth wire must be
approximately 2 cm longer than the brown (or
black) phase wire.
N
1. Connect the green and yellow (earth) wire
to the terminal which is marked with the
letter 'E', or the earth symbol
coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the letter 'N'
or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the letter
'L'. It must always be connected to the
network phase.
10
ENGLISH
L
, or
3.7 Assembly
ON-TOP INSTALLATION
1.
2.
3.
min. 100 mm
min. 55 mm
30 mm
2
+
0
4.
min. 650 mm
2
+
830 mm
0