Télécharger Imprimer la page

Frigidaire GCEH1642FS1 Instructions D'installation page 11

Publicité

5. Attach the remaining two power cord outer conductors to
the outer
brass colored terminals on the terminal block.
Tighten both screw securely.
6. Tighten the screws securing the cord restraint against the
power cord.
7. Reinstall the terminal access cover.
NON-CANADIAN ELECTRIC Laundry Center
ELECTRICAL CONNECTIONS FOR A 4-WIRE SYSTEM
1. Remove the screw securing the
terminal block access cover to the
rear panel and remove cover.
2. Install a U.L. approved strain relief
connector in the entry hole on the
back panel.
3. Remove the ground wire from the green ground screw
located above the termial block.
4. Insert a NEMA 14-30 Type ST or SRDT, U.L. approved power
cord through the strain relief.
5. Attach the green power cord ground wire to the cabinet
with the green ground screw.
6. Attach the white (neutral) wire from the power cord and
the ground wire from the appliance harness to the silver-
colored center terminal on the terminal block. Tighten the
screw securely.
7. Attach the red and black wires from the power cord to the
outer brass-colored terminals on the terminal block. Tighten
both screws securely.
8. Tighten the screws securing the cord restraint firmly against
the power cord.
9. Reinstall the terminal block access cover.
INSTALLATION
LEVELING THE LAUNDRY CENTER
Excessive noise and vibration can be prevented by properly leveling
the washer.
1. With the laundry center in it's final position, place a level ontop
of the laundry center. Adjust the leveling legs so the laundry
center is level front-to-rear and side-to-side, and stable corner-
to-corner.
Press down on alternate corners and sides and feel for the
slightest movement. Adjust the appropriate leg so the washer
is SOLID on the floor on ALL four legs. Keep the leveling leg
extension at a minimum for best performance of the laundry
center.
WASHER CONNECTIONS
1. Run some water from the hot and cold faucets to flush the
water lines and remove particles that might clog up the water
valve screens.
2. Check inlet hoses to ensure the rubber washers are installed in
each end.
3. Carefully connect the inlet hoses to the water valve (on the
left side of the washer cabinet), tighten by hand, then tighten
another 2/3 turn with pliers.
DO NOT CROSS THREAD OR
CAUTION
OVERTIGHTEN THESE CONNECTIONS.
4. Determine which water faucet is the HOT water faucet and
carefully connect the bottom inlet hose to the HOT water faucet,
tighten by hand, then tighten another 2/3 turn with pliers.
Carefully connect the top inlet hose to the COLD water faucet,
tighten by hand, then tighten another 2/3 turn with pliers.
DO NOT CROSS THREAD OR
CAUTION
OVERTIGHTEN THESE CONNECTIONS.
Turn the water on and check for leaks at both connections.
GAS CONNECTION (Gas laundry centers only)
1. Remove the shipping cap from gas pipe at the rear of the dryer.
NOTE: DO NOT connect the laundry center to L.P. gas service
without converting the gas valve. An L.P. conversion kit must
be installed by a qualified gas technician.
2. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved pipe
from the gas supply line to the 3/8 inch (0.96 cm) pipe located
on the back of the dryer. Use a 1/2 inch (1.27 cm) to 3/8 inch
(0.96 cm) reducer for the connection. Apply an approved thread
sealer that is resistant to the corrosive action of liquefied gases
on all pipe connections.

Publicité