10� Technical specifications
Dimensions W x H × D
Supply voltage
Power consumption (P on )
Luminous flux
Efficiency
Standby sensor (P sb )
Colour temperature
Colour rendering index
Average rated life expectancy
Colour consistency SDCM
Luminous intensity distribution
Material
HF technology
Angle of coverage
Time setting
Twilight setting
IP rating
Protection class
Power consumption
Ambient temperature
Transmitter power
11� Troubleshooting
Malfunction
Sensor-switched light without
power
Sensor-switched light will not
switch ON
Sensor-switched light will not
switch OFF
Sensor-switched light switches
ON without any identifiable
movement
Sensor-switched light does not
switch ON despite movement
300 × 300 × 65.5 mm
220 – 240 V, 50/60 Hz
8.80 W
886 lm
101 lm/W
0.39 W
3,000 K (warm white)
R a  = 82
L70B50 at 25 °C: > 60,000 hours
Starting value: 3
150°
180°
150°
120°
120°
90°
90°
50
100
150
60°
60°
200
250
30°
30°
C0 / C180
C90 / C270
cd / 1000 lm
plastic
5.8 GHz
360° with 160° angle of aperture
15 s to 15 min
2 – 2,000
IP 20
II
630 mW
-10 °C to +40 °C
approx. 1 mW
Cause
• Fuse has tripped, not switched ON,
break in wiring
• Short circuit in mains power supply lead
• Any mains switch OFF
• Incorrect twilight setting selected
• Mains switch OFF
• Fuse has tripped
• Continued movement within the
detection zone
• Light not mounted for detecting mo-
vement reliably
• Movement occurred, but not identified
by the observer ( movement behind
wall, movement of a small object in
immediate light vicinity etc. )
• Rapid movements are suppressed to
minimise malfunctioning or detection
zone set too small
• Incorrect twilight setting selected
- 13 -
Remedy
• Activate, change fuse, turn ON mains
switch, check wiring with voltage
tester
• Check connections
• Switch on mains switch
• Readjust
• Switch ON
• Activate, change fuse,
check connection if necessary
• Check detection zone
• Securely mount enclosure
• Check detection zone
• Check detection zone
• Readjust