Télécharger Imprimer la page

Briggs & Stratton VANGUARD Battery Charger - 3000W Manuel D'utilisation page 5

Masquer les pouces Voir aussi pour VANGUARD Battery Charger - 3000W:

Publicité

3.
Reduced charger output is caused by the conditions that follow:
a.
Low AC input voltage: Check the AC power.
b.
High ambient temperature: Move the unit to cooler surroundings.
Alarms
If an alarm stops the charger, the display shows a code. Refer to the chart that follows to find the condition that the charger is in.
<A> <alarm code identified with a 2 digits code>
Alarms
CODE
A01
A02
A03
A05*
A07
A08
A09
A10
A13
A14
A15
A16
A17
A18
A23
A24
A25
A26
A27
A28
A29
S-S
* The charge restarts once the battery temperature reaches a value lower than 45°C
ALARM TYPE
LOGIC FAILURE #1
CAN BUS KO
WATCHDOG
HIGH BATTERY TEMPERATURE
OVERCURRENT
HIGH TEMPERATURE
MISMATCH VOLTAGE
TIMEOUT
BATTERY DISCONNECTED
FAN ERROR
THERMAL SENSOR FAILURE
LOGIC FAILURE #2
FLASH CHECKSUM
EEPROM CHECKSUM
POWER FAILURE #1
WRONG INPUT MAINS
SHORT OUTPUT
WRONG MARKER EEP
NO MAINS
LOW TEMPERATURE
CLOCK BATTERY OFF
START STOP OPEN
c.
There is blockage to the cooling airflow. Move the unit to a open space and
check the charger cooling fins for too much dust, dirt and debris. See Clean
the Charger.
If the battery still does not charge, speak to an Authorized Battery Service Dealer for
instructions.
DESCRIPTION
Trouble with current detection
Trouble with CAN communication
The logic board is not working
The temperature of the battery is higher
than 55°C
Over current
The battery charger is at a high
temperature
Battery voltage sensing error
Phase 1 finished for timeout
Battery is disconnected
The fan is not working not correctly
The thermal sensor is not connected
Logic supply failure
The microcontroller Flash memory is
corrupted
The EEPROM or flash memory is corrupted YES
The output current sensing circuit is
damaged
The input mains level is out of the operating
range
Short circuit at the output stage
The EEPROM or Flash memory is
corrupted
Input grid failure
The internal temperature of the charger is
below -30°C
The clock calendar battery is discharged or
not connected
The charger is set to the REST status
by the user with the CanConsole or, the
interlock is open.
STOP
YES
No
YES
Temporary
Temporary
Temporary
Temporary
YES
Temporary
No
No
Temporary
YES
YES
YES
YES
YES
Temporary
Temporary
No
Yes
5

Publicité

loading