8. LED INDICATORS
The possible combinations of LEDs and their meaning are:
0 = LED OFF
1 = LED ON
2 = Flashing LED
LINE/
LOW
ERROR
1
0
1
1
1
0
1
1
2
0
9. TECHNICAL DATA
Liquid temperature: ......................... 4ºC - 40ºC
Ambient temperature: ..................... 0ºC - 40ºC
Storage temperature: ................... -10ºC - 50ºC
MEDIUM
PUMP STATUS
Functions
0
"Standby" mode. Equipment in tension, engine stopped.
0
LOW speed
1
MEDIUM speed
1
HIGH speed.
Error
0
An error has occurred in the electronic system.
Try to reset the pump by disconnecting and reconnecting the
power.
If the error persists, contact the technical service
12
ontroller (aux terminals)
Ambient relative humidity, max.: ............... 95%
Motor class I.
Other data see Figure 3.