Télécharger Imprimer la page

Samsung DVG45R6100P Manuel D'utilisation page 34

Publicité

Installation
Running the vent blockage test
1. Make sure the drum is empty, and then close the door. (If there are any clothes or other items in the
drum, the test will not give accurate results.)
2. Press the Power button to turn the dryer on, then simultaneously press and hold the Adjust Time
and Dryness buttons for 3 seconds. " InS" appears in the dryer's display. (If you have started other
procedures before the Vent Blockage Test, the dryer will not enter the Vent Blockage Test mode.)
3. Press the Start/Pause (Hold to Start) button. The Vent Blockage Test starts immediately. During the
test, the number indicator makes a circle in 6 clockwise steps. The test takes about 2 minutes. Do not
open the door during the test.
4. After 2 minutes, when the test is complete, the results are displayed and the dryer sounds a tone. If
status of the duct system is normal, " 0" appears and the dryer sounds a completion tone. If the duct
system cannot exhaust properly, the check code appears, and the dryer sounds an alarm tone. For
description about the code, see the "Installation check codes" section on page 35.
If there are any other problems, an information code appears in the display. For description about the
code, see the "Information codes" section on page 58.
-
To stop or cancel the Vent Blockage Test, press the Power button to turn off your dryer.
-
The results remain on the display for about 5 minutes and then automatically turn off. You can turn
the results off immediately by pressing the Power button.
NOTE
• During or after the test, the internal drum is hot. Use caution to prevent burns. The Vent Blockage Test
is used to check for problems in the current duct system when the dryer is installed for the first time.
• If the test result displays check code (the duct system is blocked ), refer to the " Ducting requirements"
section on page 19 and the "Exhaust ducting guide" section below, and then take proper measures to
correct any problems. If the test is suspended, it could result in incorrect results. Follow the proper
procedures when testing the dryer.
• Even if the test result is normal (" 0"), the duct system could be blocked slightly. Properly install all duct
work according to the installation instructions in this manual.
34
English
Untitled-1 34
Untitled-1 34
2024-09-03
2024-09-03
6:20:14
6:20:14

Publicité

loading