Cleaning
The product is to be cleaned with hot water or a mild soapy cleaning agent .
To see which cleaning products have been tested and approved by Pressalit
for the specific product, please visit Pressalit .com and refer to the product's
item number . Pressalit recommends cleaning the product after installation .
Always read the material safety data sheet (MSDS) and supplied
instructions of the cleaning, disinfecting or de-scaling agent and comply
with instructions for safe use, dilution, rinsing, drying, handling and
storage of the agent .
• Do not use an autoclave or other type of steam cleaner .
• Avoid aggressive cleaning agents containing acids .
• Never spray the product directly with a high pressure cleaner .
• Avoid use of abrasive, corrosive or chlorine-based cleaning or
disinfecting products .
Trouble-shooting
Symptom
The call button does
not work .
The support arms
drop down to fast .
The support arms are
loose/unstable .
CAUTION
!
IMPORTANT
Cause
The plug for the button
has been pulled out .
The adjustment screws
are too loose .
The mounting screws
have become loose .
Action
Put the plug back into
the socket .
Tighten the three
adjustment screws .
See "Adjustment" .
Tighten the mounting
screws .
See "Maintenance" .