2. DESCRIPTION DU PRODUIT
Diesel direct-fired mobile/portable space heater with open combustion chamber
3. SPECIFICATIONS TECHNIQUES
Model
Heat Input [kW] *
Air Flow Rating [m³/h] / btu/h
Fuel Type
Fuel consumption [L/h]
Fuel Nozzle Size [gph]
Voltage [V/Hz]
Air Pressure Setting [bar]
Current Rating [A]
Electrical Power [W]
Fuse Rating
Dimensions
Net Weight (kg)
Length (mm)
Width (mm)
Height (mm)
Tank Capacity (l)
Operating range (h)
Standard Accessories
Fuel gauge
Handle
Ambient thermostat
Malfunction detection light
* Based on Gross Calorific Value [Hs]
WTCAC50R-DU
50 kW
1100 m³/h
170600 btu/h
Diesel - Kerosene
4.0 l/h
0.8 gph
220-240V~
50Hz
0.32 bar
1.48 A
230 W
T3.15A
24.5 kg
1065 mm
480 mm
695 mm
56 l
14 h
yes
1
integrated
integrated
45