TFA_No. 30.3907_Anleitung
TFA-ID transmitter ID-A5 POOL – Transmitter pool thermometer
10. Troubleshooting
Problem
Solution
➜ Ensure the batteries' polarities are correct
No display
➜ Change the batteries
on the transmitter
➜ Check the transmitter's batteries
No transmitter reception
via TFA.me station/
gateway
➜ Restart the transmitter and the base station/
➜ Manual search for the transmitter
➜ Choose another place for the transmitter
➜ Reduce the distance between the transmitter
➜ Check if there is any source of interference
➜ see above
No display
➜ For more information and a detailed descrip-
of the water temperature
in the TFA.me portal
➜ Change the batteries
Incorrect indication
If your device fails to work despite these measures, please contact the retailer
where you purchased the product from for advice.
11. Waste disposal
This product and its packaging have been manufactured using high-grade mate-
rials and components which can be recycled and reused. This reduces waste
and protects the environment.
Dispose of the packaging in an environmentally friendly manner using the collec-
tion systems that have been set up.
Disposal of the electrical device
Remove non-permanently installed batteries and rechargeable batteries
from the device and dispose of them separately.
18
31.10.2024
15:51 Uhr
Seite 10
(only use batteries/rechargeable batteries with
1.5V voltage!)
gateway according to the manual
(according to the manual)
and/or the base station/gateway
and the base station/gateway
tion, go to go.tfa.me
TFA-ID transmitter ID-A5 POOL – Transmitter pool thermometer
This product is labelled in accordance with the EU Waste Electrical and
Electronic Equipment Directive (WEEE). This product must not be dis-
posed of in ordinary household waste.
As a consumer, you are required to take end-of-life devices to a desig-
nated collection point for the disposal of electrical and electronic equip-
ment, in order to ensure environmentally-compatible disposal. The
return service is free of charge. Observe the current regulations in
place!
Disposal of the batteries
Never dispose of empty batteries and rechargeable batteries with ordi-
nary household waste. They contain pollutants which, if improperly dis-
posed of, can harm the environment and human health. As a consumer,
you are required by law to take them to your retail store or to an appro-
priate collection site depending on national or local regulations in order
to protect the environment. The return service is free of charge.
The symbols for the contained heavy metals are:
Cd=cadmium, Hg=mercury, Pb=lead.
12. Specifications
Measuring range
Temperature
-40°C...60°C
Resolution
0,1°C
Precision
±1°C from 0...50°C, otherwise ±1,5°C
Energy supply
Batteries 2 x AA 1,5 V (not included)
We recommend Alkaline batteries
Battery life
ca. 1 year (with Alkaline batteries)
Transmission frequency
868 MHz
Maximum
radio-frequency power
< 25mW
Range
max. 100 m (open field)
Transmission interval
Every 5 minutes
19