INSTALLATION
In order to adapt the cooker to burn a different
type of gas, you should:
exchange nozzles (see tables below),
adjust the "economical" flame.
Somipress burner(marked „SOMI-
press" on the burner body)
Nozzle diameter
Auxiliary
Heat load
Gas consumption
Nozzle diameter
Medium
Heat load
Gas consumption
Nozzle diameter
Large
Heat load
Gas consumption
Burner flame
Full
Economical
In order to perform adjusting operations, take off the knobs.
Caution!
The cookers provided by the manufacturer
have burners which are factory-adapted to
use the gas specified on their data plates and
guarantee cards.
G20 2E -
20mbar
G25 2L -
25mbar
mm
0,72
kW
1,00
g/h
-
mm
0,98
kW
1,80
g/h
-
mm
1,17
kW
2,80
g/h
-
Re-arming from liquid
gas
to natural gas
1. Exchange a burner nozz-
le for the appropriate type
according to the nozzle
table.
2. Unscrew an adjusting
bolt slightly and adjust the
flame size.
84
Gas type
G30 3B/P -
G30 3B/P -
30mbar
50mbar
0,52
0,45
1,00
1,00
73
-
0,67
0,58
1,80
1,80
131
-
0,83
0,75
2,80
2,80
204
-
Re-arming from natural
gas
to liquid gas
1. Exchange a burner
nozzle for the appropri-
ate type according to the
nozzle table.
2. Screw in an adjusting
bolt slightly and check the
flame size.
G25.3 2K -
25 mbar
0,71
1,00
-
0,98
1,80
-
1,17
2,80
-