INSTALLATION
Caution!
The cooker may only be connected
to a liquid gas cylinder or the existing
gas supply by an authorised fitter,
observing all safety rules.
Connection with a flexible steel hose.
If the cooker is connected according to the
class 2 specifications, sub-class I, only fle-
xible metal hose can be used which meet
the valid national regulations. Gas feeding
connector must be G ½" threaded coupling.
Use only pipes and fittings that meet the
requirements of the valid standards. Maxi-
mum admissible length of the flexible hose
is 2000 mm.
Make sure the connection is not touching
any mobile elements which could damage
the hose.
Connection with a stable pipework.
The cooker comes with a G ½" threaded
coupling.
The connection to gas supply must be done
in a manner that excludes stresses in any
point of the pipework or parts of the appliance.
Make sure you do not exceed the torque
when making the connection (maximum
torque is 18 Nm). Otherwise, the connection
may be faulty or leaks may occur.
The gas hose should not touch metal ele-
ments of the cooker back shield.
Important!
Each time you replace a reducer
carry out technical inspection of the
cooker that covers gas valves and
proper operation of the flame failure
cut-off device.
Caution!
On completion of the cooker installa-
tion, the tightness of all connections
should be checked, e.g. applying
water with soap.
Do not use fire to check tightness.
Electrical connection
 The cooker is manufactured to work with
a one-phase alternating current (230V
1N~50 Hz) and is equipped with a 3 x 1,5
mm
connection lead of 1.5 mm length
2
with a plug including a protection contact.
 A connection socket for electricity supply
should be equipped with a protection pin
and may not be located above the coo-
ker. After the cooker is positioned, it is
necessary to make the connection socket
accessible to the user.
 Before connecting the cooker to the sok-
ket, check if:
- the fuse and electricity supply are able to
withstand the cooker load,
- the electricity supply is equipped with an
efficacious ground system which meets
the requirements of current standards
and provisions,
- the plug is within easy reach.
Adapting the cooker to another
type of gas.
This operation may only be carried out by an
appropriately authorised fitter.
If the gas the cooker is to be supplied with
differs from the gas provided for the cooker
by the manufacturer, that is G20 20 mbar,
burner nozzles must be exchanged and the
flame needs to be adjusted.