MESSAGE
SWITCH LIFT ON
MOVING LEFT
MOVING RIGHT
FINAL LIMIT
CHECK KEY
CHECK SWIVEL
EDGE
END STOP
MULTIPLE CALLS
BRAKE
RELAY FAULT
WHAT IT MEANS
Stairlift is parked on a working charge point but
the on/off switch is in the '0' (off) position. The
stairlift will not charge up in this state unless the
on/off switch is switched to the 'I' (on) position.
Lift travelling left.
Lift travelling right.
These messages cycle.
Lift has been stopped by a safety sensing edge.
If the lift is at the end of the rail the display will
read 'END STOP' until the controller is released.
If the stairlift is not at the end of the rail it will have
been stopped by the 'END STOP' safety sensing
edge.
More than one controller is being pressed at the
same time.
Motor brake has been activated.
Power relays did not close.
ACTION TO TAKE
Check the on/off switch is in the I position.
No action.
No action.
1. Check the key is in the arm rest and switched
on.
2. Check the seat is swivelled into the correct
position.
Ensure that both the track and the staircase are
free from obstructions.
Ensure that both the track and the staircase are
free from obstructions.
Check there are no buttons pressed in on
remote controls.
Turn charger off at wall socket and turn lift
off. Wait for around one minute before turning
everything back on. If the problem persists
contact your local stairlift service centre.
1. Ensure the lift is parked on a charge point
and the charger is turned on.
2. Turn charger off at wall socket and turn lift
off. Wait for around one minute before turning
everything back on. If the problem persists
contact your local stairlift service centre.