11. Troubleshooting guide
| English |
Case 1. Starting failure
CHECK
PROBABLE CAUSES
ACTION
EEN
EE
Ee
fuel filter
=>
fuel filter is clogged
clean
carburetor adjustment screw
—+
out of normal range
=
adjust to normal range
sparking (no spark)
=>
spark plug is fouled/wet
=>
clean/dry
=>
plug gap is incorrect
—+
correct (GAP: 0.6 — 0.7 mm)
spark plug
=>
disconnected
retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK
PROBABLE CAUSES
ACTION
fuel tank
incorrect fuel or staled fuel
drain it and with correct fuel
carburetor adjustment screw
out of normal range
adjust to normal range
muffler,cylinder (exhaust port)
=>
carbon is built-up
=>
wipe away
air cleaner
=>
clogged with dust
wash
cylinder fin, fan cover
clogged with dust
=>
clean
When your unit seems to need further service, please consult with our service shop in your area.
11. Guide de localisation des pannes
1er cas : Défaut de démarrage
ep
VERIFICATION
CAUSES PROBABLES...
ION
ée
réservoir de carburant
carburant incorrect
vidanger et remplacer le carburant
filtre à carburant
filtre à carburant colmaté
nettoyer
vis de réglage de carburateur
=>
déréglé
refaire le réglage
allumage
bougie sale ou noyée
nettoyer ou sécher
Jeu d'électrodes incorrect
—+
régler le jeu (de 0,6 à 0,7 mm)
Bougie d'allumage
débrancher
resserrer
2ème cas : Le moteur démarre mais ne reste pas en marche ou est difficile à redémarrer
e
V E R I F I C A T I O N
a
CAUSES FROBABLES enee
réservoir de carburant
carburant incorrect
vidanger et remplacer le carburant
vis de réglage de carburateur
=>
déréglé
refaire le réglage
silencieux, cylindre
dépôt de calamine
retirer
filtre à air
colmaté de poussière
=>
nettoyer
ailette de cylindre/flasque de ventilateur
colmaté de poussière
nettoyer
Si la machine nécessite des opérations d'entretien plus élaborées, contacter le centre de service après-vente le plus proche.
11. Guía de localización y solución de problemas
| Español |
Caso 1. El motor no arranca
COMPROBAR
POSIBLES CAUSAS
ACCIÓN
"Tanque
de combustible.
— Combustible incorrecto.
> Vaciar y llenar con el combustible correcto
Filtro de combustible
=
El filtro de combustible está obstruido.
Limpiar
Tomillo de ajuste del carburador
Fuera del margen normal
Ajustar al margen normal
Explosión (no hay chispa)
La bujía está sucia/mojada.
>
Limpiar/secar
La distancia interelectródica es incorrecta —
Corregir (DISTANCIA INTERELECTRODICA: 0,6 - 0,7 mm)
Bujía
Desconectada
Reajustarlo
Caso 2. El motor arranca pero no se mantiene en marcha./Dificultad para volver a arrancar el motor.
COMPROBAR
POSIBLES CAUSAS
ACCIÓN
Tanque de combustible
Combustible incorrecto
Vaciar y llenar con el combustible correcto.
Tornillo de ajuste del carburador
=>
Fuera del margen normal.
Ajustar al margen normal.
Silenciador, cilindro (lumbrera de escape)
Acumulación de carbón
=>
Quitar
Filtro de aire
=>
Obstruido con polvo
=>
Lavar
Aletas del cilindro, cubierta de ventilador
Obstruidas con polvo
=>
Limpiar
Si le parece que la unidad necesita otros servicios, consulte nuestro centro de servicio en su área.