5 – The manufacturer and / or installer must give each customer a file showing that the products used do not emit any
dangerous substance beyond the maximum authorized levels, specified in the appropriate European standards or in
other national specifications, in the event of fire (EN 13241-1 §4.2.9).
6 – The installer is required to ensure the traceability of assembly and inspection operations effectively carried out (EN
13241-1 §6.4).
7 – The staff of the company installing the equipment, and / or staff of the user company in charge of specific functions, such
as maintenance, must be qualified, trained and certified in the case of particularly risky work, such as work under power
(D. Safety at work 89/655/EEC modified 95/63/EEC art.7 / CT art. R 233-2).
8 – The final user must carry out the periodical yearly or twice-yearly checks, or have them carried out, with keeping of a
maintenance register (D. Safety at work - 89/655/EEC modified 95/63/EEC - art. 4b / CT R 233-1-2 and R 233-11-
1).
2 – CHARACTERISTICS
This manual system, with a bichromated rail, is designed to fit horizontal sliding doors with specific characteristics
(isothermal, acoustical, clean-rooms, dust-tight ...).
When the door is closed, frame and floor tightness is insured by 2 fixed rollers moving down in the rail notches.
When the door is opened, the 2 fixed rollers come out of the notches and the door moves away from the frame and the floor.
An opening and closing butt limit the door movement.
This system is suitable to doors of dimensions and weights as per table here-below, whatever door or frame materials are
used.
13 references correspond to 13 doors widths (8 for 4440 systems and 5 for 4460 systems):
The operating temperature is between -30°C and +55°C.
The maximum noise level when the door is operated is lower than 85dB (A).
These FERMATIC have been designed to resist to differential pressure class 4 (1000 Pa) for external doors installed ouside a site
as defined in the norm EN 12424:2000. . For external door installed inside a site, differential pressure is class 4 for doors < 10,5m²
or class 3 for doors > 10,5m² .
Specific Options
Lock
Simple or double kit gasket
Manual system FERMATIC 4440
Door height
Mini
----
Maxi
4500 mm
Référence
Door width (mm)
4441
840
4442
1141
4443
1441
4444
1741
4445
2041
4446
2341
4447
2641
4448
2941
4461
3241
4462
3841
4465
4601
4466
5201
4467
5801
Equipements
Door
Thickness
weight
100 mm
160 mm
400 Kg
Door height
1140
4500
1440
4500
1740
4500
2040
4500
2340
4500
2640
4500
2940
4500
3240
4500
3840
4500
4600
4500
5200
4500
5800
4500
7000
4500
Ref
37 – 237HP
4448 - 4467
- 7 -
Door
----
NM4440/NG-A