1 – GENERAL INFORMATION
1.1 - Regulations & Obligations
The product you have acquired is integrated into an industrial door. Its being put on the European Union market implies EC
marking by a certified agency, under the liabilities of the manufacturer and / or installer of the door.
The design, manufacture and installation of an industrial door must respect the essential requirements of health and safety
determined by the following European directives:
Construction Products Directive 89/106/EEC
Low Voltage Directive 73/23/EEC
Electro-magnetic Compatibility Directive 89/336/EEC
Machines and Working Equipment Directive 98/37/EEC
The proof of conformity to the regulation texts, mentioned above, is obtained by the respect of the standard reference
detailed by the standard of product NF EN 13241-1. - Industrial, Commercial and Garage Doors (Part 1: products without
fire and smoke proofing characteristics).
Terminology
standard
EN 12433-1
Types of doors
EN 12433-2
Components of doors
FERMOD has taken the standards that apply to the supplied products into consideration
1.2 – Liabilities
1 – The manufacturer of the door, the installer and the user must observe the safety rules (collective protection, individual
protection) applicable during transport, assembly, use, and discarding of the door or its components.
2 – The liability of the user may be engaged in circumstances that are not marginal. Thus, the user must scrupulously comply
with the recommendations for storage, assembly, use, maintenance, health and safety, use-by date, etc. supplied by the
manufacturer.
Likewise, where the producer be held liable for the non-conformity of the product, the user may also share the liability,
insofar as he has not, from his side, checked this conformity, even if the product in question is administratively in
conformity. The user is also held liable if he himself increases the fault in the product. The liability of the manufacturer
can be reduced or eliminated, taking all the circumstances into consideration, when the damage is caused jointly by the
product, and by the fault of the victim or a person for whom the victim is responsible (D. general safety of products
92/59/EEC and D. liability from the fact of faulty products 85/374/EEC).
3 – Safety devices fitted to the doors are not intended to prevent any wilful act of the operator or persons nearby (EN12604
§4.1.2).
4 – The choice of options follows the type of door installed. It is the manufacturer's responsibility to ensure the compatibility
of accessories according to the characteristics of the door and the conditions of use (EN12604 § 4.2.1).
European Directives
Safety standard
EN 12604
Mechanical aspects
EN 12605
Test methods
EN 12453
Safety of use
EN 12445
Test methods
EN 12978
Safety devices
EN 12635
Installation and use
- 6 -
Manual Door
X
Environmental
standard
EN 12424
Resistance to wind
EN 12444
Tests and calculations
EN12425
Water penetration
EN 12489
Test methods
EN 12426
Permeability to air
EN 12427
Test methods
EN 12428
Thermal transmission
Motorised door
X
X
X
X
Electrical and standard
EN 60204-1
Machine electrical safety
EN 61000-6-2
Immunity to industrial environment
EN 61000-6-3
Harmonic measure emission
EN 61000-6-4
Industrial environment emission
.