structions contained herein will allow you to use
the appliance in a safe manner.
Make sure the power supply cable has not been damaged.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard. Moreover, check if the technical
parameters of power supply source comply with the requi-
rements specified on the rating plate. Place the appliance
in its upright position. Make sure the switch is in its "0" posi-
tion shown in Fig. 3. Connect the heater to the power supply
source. Turn the switch and leave it for 5 seconds in the
positions as follows:
► Fan only: Fig. 3;
► 1st degree of heating: Fig. 3, and
► 2nd degree of heating: Fig. 3.
►►5. SWITCHING OFF
Turn the switch to its "0" position. Once the heating is off,
leave the fan operating for 3 minutes.
►►6. WORK WITH THE HOSE DISTRIBUTING
HOT AIR ( FIG. 7 )
The appliance is adapted to work with a hot air
hose
distributor
up
ting hot air of Ø305 mm (B 18 EPR) / Ø407 mm
(B 30 EPR) and max 15m length shold be connected to the
outlet. After connection make sure that the hose is patent
and not folded to let the air flow property.
►►7. THERMAL CIRCUIT BREAKER "RESET"
The appliance has been equipped with an integrated thermal
circuit breaker ensuring high safety level. The breaker will
automatically switch the power supply off once a limit tempe-
rature is exceeded. Should it happen, let the appliance cool
down and only then, look for the reason of the problem. Next
push the "RESET" button (Fig. 4) with a pointed tip in order
to unlock the thermal circuit breaker. If the heater does not
operate, contact the seller or approved service centre.
►►11. TROUBLESHOOTING
PROBLEM
The motor operates while the appliance
does not heat
The motor does not operate while the
heating elements are hot
The whole appliance does not operate
Reduced air flow
o
100
C.
The
hose
distribu-
Thermal circuit breaker is active
Thermostat has been damaged
Relay has been damaged
Heating element has been damaged
Motor has been damaged
Fan has been stopped
Switch has been damaged
Electric circuit open
Switch has been damaged
Foul air duct
Motor has been damaged
►►8. OUT OF SEASON STORAGE
Should the appliance remain idle for a long period of time,
clean it before shoving by blowing the inside with compres-
sed air. The heater should be kept in a dry and clean place.
Before you start using it again make sure the power supply
cable has not been damaged. In the case of any doubts con-
tact the seller or approved service centre.
►►9. FUNCTIONAL INSPECTION
The appliance should be checked at least once a year by
competent service personnel approved by the manufacturer.
Any inspections or repairs should be conducted by compe-
tent personnel only.
►►10. EXTERNAL THERMOSTAT
The appliance may work with external thermostat.
Heating without room termostat
The unit runs under continuous duty.
► Connect the supplied bridge circuit plug 2 Fig. 6 to the
thermostat socket 1 Fig. 6 of the unit.
► Put the switches into the desired position
► WARNING: For optimum unit operation, the device should
not be operated at an ambient temperature above 25°C.
Heating with room thermostat
The unit runs fully automatically and is dependent on set
temperatures.
► Remove the bridge circuit plug 2 Fig. 6
► Connect thermostat plug 3 fig 6 of the room thermostat
(accessories) to the thermostat socked 1. Fig. 6
► Put room thermostat 4 Fig. 6 in a suitable place. The ther-
mostat sensor may not be exposed directly to the hot air cur-
rent and not fixed directly on a cold surface.
► Pre-select desired room temperture on the room thermo-
stat.
► Put the switches (Fig. 3) into the desired position.
REASON
SOLUTION
Let the heater cool down and push the
"RESET" button
Replace the thermostat
Replace the relay
Replace the heating element
Replace the motor
Unlock / clean the fan
Replace the switch
Check power supply connection
Replace the switch
Open the air duct
Replace the motor