Residual hazards
{
Danger!
Dangerous voltage
All power connections carry dangerous voltages both if the motor is at
standstill and after up to 3 minutes after mains switch off.
Possible consequences:
Death or severe injuries after touching the power connections.
ƒ
Protective measures:
Wait for at least 3 minutes before working on the power connections.
ƒ
Check whether all power connections are de−energised.
ƒ
O
Warnings!
Conditions of Acceptability:
The products covered by this report are only intended for use with Power
ƒ
Conversion Equipment (inverters).
Appropriate cooling measures shall be taken based on the power loss data
ƒ
within the instructions available from the manufacturer.
External wiring material for models with bus bar screw connectors − R/C
ƒ
(AVLV2), rated 105 °C min., suitable for applied voltage and current. If
wiring material with a lower temperature rating is used, an additional
temperature test at the wiring material has to be conducted in the end
use.
EDKZS3X200 DE/EN/FR/ES/IT 3.0