18. Do not exceed input rating stamped on the
dataplate of the heater. Do not exceed the burner
manifold pressure stated on the dataplate. Do
not use an orifice size different than specified for
the specific input rating of this heater, fuel type
configuration and altitude.
Initial Setup
1. Plan the installation. Determine location for the
heater to optimize its heat pattern, keeping in
mind cooler regions in the house (end walls, and
curtains) and clearances to combustibles.
2. Hang the burner box. See Fig. 5. Maintain clear-
ances to combustibles as shown in Fig. 1.
3. From the burner box chain, measure the distances
shown in Fig. 6. Aligning to the center of the burner
box discharge, hang the chains at these points,
using open eye hooks.
FIG. 6 SENTINEL
BURNER BOX
A
B
C
TRUSS
HEATER
CENTERS
LENGTH
30 FT.
40 FT.
4 FOOT
50 FT.
60 FT.
30 FT.
40 FT.
5 FOOT
50 FT.
60 FT.
30 FT.
40 FT.
10 FOOT
50 FT.
60 FT.
* SUPPORT MUST BE CREATED BETWEEN THE TRUSSES
Owner's Manual • Sentinel v.2
Radiant Tube Heaters
HANGING CHAINS
D
A - B
B - C
(FT.)
(FT.)
4
4
4
4
4
4
4
4
5
5
5
5
5
5
5
5
5*
5
5*
5
5*
5
5*
5
FIG. 5
E
F
HANGING CHAIN DISTANCES
C - D
D - E
E - F
(FT.)
(FT.)
(FT.)
12
8
12
8
12
8
12
8
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
G
H
F - G
G - H
(FT.)
(FT.)
12
12
8
12
12
8
5
10
5
10
10
5
5*
10
5*
10
10
5*

Publicité

loading

Ce manuel est également adapté pour:

Sentinel v.2 at125Sentinel v.2 at150