INSTALLATION INSTRUCTIONS
INSTRUCTIONS FOR POSITIONING
Keep 10 cm of gap all around the appliance.
If the walls next to the appliance are of inflammable material, they should be suitably clad.
Fire prevention regulations must be scrupulously observed.
The electric wiring must never be under strain. Do not obstruct the suction inlets or heat dispersion outlets.
Remove the protective film.
INSTRUCTIONS FOR ELECTRICAL CONNECTION AND EQUIPOTENTIAL SYSTEM
The electrical safety of this appliance is guaranteed only if it is connected correctly to an efficient earthing system, in accordance
with current safety regulations. The manufacturer shall not be responsible for any damage caused by failure to earth the installation
properly.
The appliance must also be included in a equipotential system. Make the connection through the terminal situated on the rear of
the appliance, and marked by the relevant symbol, according to current safety regulations.
In case of replacement of the power cord, the length of the wires between the connection point of the cable and the terminals must
allow the active conductors to be tightened before being earthed.
SAFETY AND CONTROL SYSTEMS
Auxiliary circuit switch
Restoring the safety thermostat If, during its use, the machine should turn off due to the triggering of the safety thermostat, you
Fuses positioned next to the terminal board protect the electric circuit
can reset it, thus removing the heating unit present in its lower part. Then you can proceed as
follows:
• Disconnect the device from the power supply and open its door.
• Using a tool, unscrew the screw that secures the heating unit to the device chamber. Slightly
lift the front of the heating unit and remove it from the device by pulling it out from the front.
• Empty any humidification water present in the collection tray located in the upper part of the
heating unit.
• To reset the safety thermostat, overturn the heating unit as its position is indicated on its lower
part (see symbol alongside).
• Using a tool, unscrew the screw located near the safety thermostat symbol in order to access
the reset button. With the tip of a tool, enter the reset hole by pushing slightly until its reset.
• Then tighten the screw all the way in order to avoid moisture infiltration while using the
device.
Important!
Avoid connecting the heating unit to the power supply once extracted from the
device chamber.
Avoid connecting the equipment to the power supply before repositioning the
heating unit in its original position and fastening it to the device chamber with the
previously removed screw.
21
GB
Ed. 0323