Configuration

10. Configuration
A local connection is required to configure the unit for the first time. Once this first configuration has been carried
out, a remote connection can also be established. The processes for each case are described below.
The configuration is done through the INGEREV WEB Manager application.

10.1. Local connection

To establish a local connection the charger and computer must be connected to the same communication network.
The local connection can be done through an Ethernet network.

10.1.1. Local connection via Ethernet

To make the connection, follow these steps:
1.
Connect the computer to the unit using one of the available Ethernet connectors (J12 or J13).
2.
On the laptop computer, open the web browser and open http://SerialNum.local:8080, where SerialNum
corresponds to the unit's serial number (for example, http://6H0576543210.local:8080). The serial
number is the unit's unique identification and is located on the specifications plate.
3.
Enter the username and password. The username and password are specified on the documentation
delivered with the unit.
4.
Follow the instructions given by INGEREV WEB Manager.
CAUTION
Certain operating systems may reject the above URL due to their settings. In these cases, proceed as follows:
1.
Connect the laptop computer to the unit's J12 connector using an Ethernet cable. The J13 connector
does not allow this access method.
2.
In a web browser access http://192.168.1.33:8080.
3.
Follow the steps given in the browser to carry out the configuration process.
ABT2012IQM01_B - Installation and Operation Manual
J12
J13
Ingeteam
EN
ES
FR
IT
33