Troubleshooting

12. Troubleshooting
CAUTION
Station troubleshooting must be performed by qualified personnel in compliance with the general safety
instructions in this manual.

12.1. Alarms

Alarm
Emergency push-button
The emergency stop button is pressed
Connector lock fault
Fault in the connector lock
Error in the charging station-electric
EV communication error
vehicle communication
Insulation fault
Insulation impedance below limits
The charging station temperature is out
Temperature out of range
of operating range
RFID reader error
Fault in card reader
AC grid voltage or frequency out of the
Network out of range
defined range
A parameter in the charger is outside
Device fault
the operating range
ABT2012IQM01_B - Installation and Operation Manual
Description
Release the emergency stop button
Disconnect the connector and check its functionality and
integrity. If the problem persists, contact Ingeteam.
Restart the charge process. If the problem persists,
contact Ingeteam.
Disconnect the connector from the vehicle. Check if
the insulation fault has disappeared. If this is the case,
the fault is caused in the vehicle, therefore it must be
inspected at your regular workshop.
If the insulation fault persists, contact Ingeteam.
Check that the radiators are clean and that the fans
function correctly.
Protect the unit from direct exposure to sunlight.
Ensure the ambient temperature is within the operating
range.
Hold the card near the RFID reader.
If the problem persists, contact Ingeteam.
Verify that the wiring is correct. Check connections.
Check that the voltage or frequency of the electric grid is
within range.
If the fault is temporary, it will disappear automatically.
If it persists, write down the code displayed and contact
Ingeteam.