6
Care and maintenance
6.1
Care and maintenance
CAUTION
Never use aggressive detergents.
6.2
Transport, packaging, storage
Always check that the delivery contents are complete and that they have not been damaged during transport,
immediately after receipt. In the event of transport damage, the carrier must be informed. When returning the sensor,
always ensure that it is sent in sufficiently protective packaging.
Complaints must be made as soon as a defect is detected. Claims can only be lodged within the applica-
ble time limits.
6.3
Waste disposal
Electronic components are subject to special waste regulations and may only be disposed of by specialist waste
disposal firms.
7
Technical data
Electrical data
Operating voltage UB
No load current
Permissible cable length
Signal outputs (1...32)
Switching frequency (signal output)
Trigger input
Mechanical data
Housing material
Protection
Ambient temperature range
Storage temperature range
Connection technology
Pin 8 at FT 50 C....S1L8 has to be set as a trigger input by operating key of color sensor.
32
24 VDC +/- 10%
< 250 mA
Power Supply: max 3 m, other: max. 30 m
32 x PNP (max 90 mA per output)
total current limited to 1 A
166 Hz (combination with FT 50C...S1L8)
max U
B
Plastic
IP 20
0 to + 50° C
0 to + 50° C
Screw clamp contact
IO - Box FT 50 C...S1L8 D - 068-14325- 26.11.2009-00
Mounting and
operating instructions