TROUBLESHOOTING
1)
If the charger does not turn on and none of the LED's illuminate.
a.
Check to make sure the AC outlet is supplying power by
plugging in a lamp, an appliance, or a voltage meter.
2)
The green LED (3) comes on immediately when charging a
discharged battery.
a.
The battery is probably defective, take the battery to the
dealer to be tested.
3)
When charging a battery the green LED never comes on.
a.
The battery may be defective, take the battery to the
dealer to be tested.
b.
The battery has an excessive current draw, remove or
disconnect the battery from the equipment.
4)
The amber LED continues to flash even with a connection to the
battery:
a.
Check the fuse in the accessory cable.
5)
Amber & Green LED are toggling.
a.
In Lead Acid/AGM mode the charger has an 80 hour
safety timer if the battery does not reach its optimal
voltage. The battery may be defective, take the battery to
the dealer to be tested.
b.
In Lithium mode the charger has an 18 hour safety timer if
the battery does not reach its optimal voltage. The battery
may be defective, take the battery to the dealer to be
tested.
9
Regulatory Warnings
Federal Communications Commission (FCC)
Title 47 Subpart, 15.105(b)
Note: This equipment has been tested and found to comply with
the limits for a class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio television
reception, which can be determined by tuning the equipment off
and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and
receiver.
-
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-
Consult the dealer or an experienced radio/TV technician for
help.
Government of Canada
ICES-001: Industrial, Scientific, and Medical (ISM) Radio
Frequency Generators
This product has been tested with the listed standards and found
to be compliant with the Code of Industry Canada ES-001 and the
measurement Procedure according to CISPR 11.
CAN ICES-001(B)/NMB-001(B)