4.2
clearances around appliance (TV and valuable objects)
Flush installation without
mantel
TV bracket
Enclosure
Appliance
opening
Appliance
Flush installation with mantel
6" min.
TV bracket
2.5" min.*
2" min.
(3" max.
recommended)
B
Enclosure
Enclosure
Appliance opening
Appliance
*
TV applications were tested with the minimum enclosure dimensions and the maximum recess permissible.
This data is provided in good faith and is not a guarantee for every application and television. Care and
consideration should be taken when planning these installations to ensure the temperatures around the TV meet
all manufacturer's recommended operating temperatures. Increasing the height of the mantel and/or TV above
the fireplace opening, the protrusion of mantel and the volume of the enclosure all have the effect of reducing
the temperature above the fireplace. It is always recommended to use the optional heat management kit
when considering mounting a television above the fireplace.
Flush installation with
mantel
6" min.
TV bracket
2.5" min.*
2" min.
(3" max.
recommended)
A
Enclosure
Enclosure
Appliance opening
Appliance
WARNING
!
These applications are
only acceptable when the
Universal Heat Management
kit is installed.
See "minimum clearance to
A
mantle" section (installation
manual).
Mantle clearances reduced
B
from opening with the use of the
universal heat management
system.
clearances around fireplace
Recessed installation with
protrusion
6" min.
TV bracket
2.5" min.*
2" min.
(3" max. recommended)
Enclosure
Appliance opening
Appliance
Partially recessed installation with mantel
6" min.
TV bracket
2.5" min.*
2" min.
(3" max.
12"
recommended)
max.
Enclosure
3" min.
Appliance opening
Appliance
EN
The volume of
air must be
added to the
enclosure to
accomodate
the recessed
area.
15
W415-4193 / A-0 / 07.23.24