operating your appliance
EN
2.4.1 connecting battery backup
WARNING
!
Ensure the gas and electrical power to the appliance is turned off.
Appliance may be hot, do not service until the appliance has cooled.
note:
In the event of a power failure, your appliance can be operated using the battery backup.
Before beginning installation, turn off the gas and disconnect the electrical power supply from the
A.
appliance.
Remove the safety screen to easily access the control compartment.
B.
Locate the control board under the firebox.
C.
Unplug the USB power supply going to the control board and replace it with the battery backup wire and
D.
housing provided.
Reinstall the safety screen. The safety screen must be installed at all times during the appliance operation.
E.
Turn the gas and electrical power back on to begin operating the appliance.
F.
2.4.2 turndown
Manual adjustments to your fireplace must only be made when the appliance is off and complete cool.
Allow safety barrier to cool before making adjustment.
The BL36-2/BL46-1 models are equipped with a manual gas control knob (located on the valve) that adjusts the
flame height to suit your preference. To access the gas control knob, remove your safety barrier, control cover and
door trim (see "maintenance" section for instructions on how to remove these components.
Use only your hand to turn the gas control knob (never use tools). If the knob will not turn by hand, do not try to
repair it. Contact a qualified technician.
An optional remote control is available to turn the appliance on and off and to adjust the flame height without the
need to remove the safety barrier, refer to the instructions provided with the remote control.