Installation
To position with the pipe connector
The pipe connector can be positioned in the following ways:
B
B
28
English
Untitled-1 28
Make sure to use the pipe connector before inserting the
drain hoses. Without the pipe connector, the drain hose
will not be positioned securely inside the wall standpipe,
causing a water leak.
Over the edge of a wash basin
The pipe connector (B) must be placed at a height of
between 24 inches (60 cm) and 35 inches (90 cm) from
the floor. To keep the spout of the drain hose bent, use
the supplied plastic hose guide (A). Secure the guide to
A
the wall using a hook to ensure stable drainage.
ln a standpipe or laundry tub
A
The laundry tub (B) or standpipe (C) must be no shorter
F
than 18 inches (46 cm) and no higher or longer than 96
G
inches (245 cm). Make sure the pipe connector and the
E
D
standpipe are not airtight. The height of the standpipe
(E) must be 43 inches (1100 mm) or higher from the
floor.
C
A: Hose guide / D: Cable tie / F : Pipe Connector / G:
85 mm
• Do not extend the (Y-shaped) pipe connector using
• Make sure you face the tip of the pipe connector
WARNING
NOTE
CAUTION
an extension hose.
downwards to the drain hole. Positioning the
connector tip elsewhere can cause the drained water
to flow backward.