UK | 9 Mounting
WARNING
!
Danger of electric shock from installing
the RLS 45 O and RLS 45 K inside the pro-
tective zone. No IP protection present
(IP 00). The room air control may only be
installed outside protective zones 0, 1 or 2.
When wiring several ventilation units,
i
always use a deep/double recessed-
mounted box (recessed-mounted box
provided by customer).
Strip wires of connection cables suffi-
i
ciently.
9.7 Connecting room air controls
RLS 45 O and RLS 45 K controls
i
with 230 V. Note safety requirements
in Chapter 9.6.
Wired systems
An RLS 45 O or RLS 45 K master room air
control can have a maximum of 3 further
power units and/or slave room air controls of
a similar design added to it.
A maximum of 4 control units can therefore be
deployed in this ventilation system.
You can only combine room air con-
i
trols of the same type (either RLS 45 O
or RLS 45 K).
The RLS 45 K controls and all other room air
controls/power units are connected via the
RS 485 interface.
If further room air controls are connect-
i
ed, these must be defined as slaves in
service mode  Operating instructions
or commissioning instructions.
The relevant ventilation units are connected to
the relevant room air controls. The ventilation
units on an RLS 45 O/K are generally con-
nected directly to the Fan1 and Fan2 terminal
block.
36
Radio-controlled systems with PP 45 K
control and PP 45 EO radio module
External radio sensors and PP 45 RC units
can be connected to the PPB 30 K with these
unit combinations.
Connections
For possible combinations  Chapter 7.
To install the room air control, we always
recommend using a deep recessed-mounted
box. If connecting more than 2 units, we
recommend wiring in another recessed-
mounted box.
PPB 30 ventilation units are not suita-
i
ble for use with PP 45 LT power units.
Connecting RLS 45 O
RLS 45 O room air control is used to activate
PPB 30 O units.
1. Take off frame of room air control.
2. Connect the PPBs according to the wiring
diagram ( Appendix).
The exhaust air function is only possi-
i
ble if a PPB 30 O is connected (service
mode setting for unit type = PPB 30 O
and number of units = 1).
3. Insert room air control in the re-
cessed-mounted box and screw down to
recessed-mounted box with 2 screws.
4. Fit frame. Ensure that the sensor opening
is above the PP 45 HYI (if fitted) and that
the frame engages.
5. Start up ventilation system  Chapter 10.
Connecting RLS 45 K