1 Scope of delivery
Scope of delivery depends on the
i
system configuration.
PPB 30 O / PPB 30 K ventilation unit
● Internal cover, complete: Housing,
2 G3 air filter and front cover.
● Slide-in module (including 2 fan units and
2 ceramic heat exchangers)
● 1 extension duct 200 mm long, 1 centring
ring, 2 sealing bands.
● 1 internal housing drilling template
● These mounting instructions for final moun-
ting kit.
2 Specialist installer qualification
Shell measures may only be undertaken by a
trained specialist. Only a trained electrician
is permitted to undertake final mounting and
work on the electrics. You are considered a
trained electrician if your specialist training
and experience
● means that you are familiar with the relevant
standards and guidelines
● enables you to correctly and safely under-
take the electrical connections in accord-
ance with the wiring diagram provided and
● enables you to recognise and avoid risks
and hazards associated with electricity.
After successful installation and commis-
sioning, instruct users in the ventilation
unit and operating units.
3 Intended use
PPB 30 ventilation units with heat recovery
are used for air extraction and ventilation of
apartments, offices and similar rooms. They
are suitable for new builds as well as reno-
vation work. The housing unit's ventilation
system should be configured in accordance
with DIN 1946-6.
PPB 30 are balanced ventilation units, which
are the ideal choice for use in exhaust air rooms
(bathroom, WC or kitchen with windows)
1 Scope of delivery | UK
and aerate and ventilate the rooms at the
same time. Exhaust air mode is started
automatically depending on the setting or can
be started manually at the touch of a button
(when the button/switch is connected).
PPB 30 are stand-alone units or can be used
in groups with other PPB 30/PP 45 units.
PPB 30 can also be used in damp rooms,
protective zone 1. Combinations of PPB 30 K
units with exhaust air units (e.g. ER/ECA) are
not possible.
PPB 30 are installed in outside walls (wall
thickness 320-790 mm, installation position
with slight incline towards the outside wall)
and are connected to a permanently wired
electrical installation.
The PPB 30 models "O" for object and "K"
for comfort are available. They are operated
using the
RLS 45 K or RLS 45 O room air control.
RLS 45 K: 3 operating modes (heat recovery,
cross-ventilation, automatic mode),
5 ventilation levels, time-limited intermittent
ventilation,
time-limited switch-off, safety switch-off, Mod-
Bus, configuration with PC.
PP 45 EO radio module can be added
to integrate radio sensors.
RLS 45 O: 3 operating modes (heat recovery,
cross-ventilation, automatic mode), 5
ventilation levels, configuration using service
menu.
PPB 30 K units cannot be operated in
i
combination with an RLS 45 O.
Combinations of PPB 30 K with ex-
haust air units (e.g. ER/ECA) are not
possible.
The fan/heat exchanger unit is designed as a
duct mounting and can be removed for repair
and cleaning purposes.
PPB 30 ventilation units are only intended for
domestic use and similar purposes. No other
or additional use is intended.