Design Guide - Single Standard Installation
SINGLE STANDARD INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
35-1/2" (90.2)
*83 1/2" min.
*84 1/2" max.
(212.1 – 214.6)
*Trim will overlap
additional 3/4"
18"
(22.9)
(45.7)
8"
9"
(20.3)
(22.9)
ELECTRIC
WATER
For 24" Deep Cutouts
A trim kit (ZKW36V) is required for standard
installations.
Water And Electrical Locations
The recommended electrical location is shown in
the diagram. If the electrical location is higher than
shown, use the longer power cord provided in trim kit
(ZKW36V). Follow instructions in step 4 to change
power cord.
Water supply must be located as shown.
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Refer to Dim A on page 5 for clearances needed for
door swing.
Additional Specifications
• A separate 115 volt 60Hz., 15 or 20 amp power supply
is recommended for each product. An individual
properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
• Water line must be located on the back wall as shown.
The water line should be 1/4" O.D. copper tubing or
QuickConnect
kit (WX08X10006) between the cold
water line and water connection location, long enough
to extend to the front of the unit (8' [2.4m]). Installation
of an easily accessible shut-off valve in the water line
is required.
31-1000600 Rev. 0
6"
(15.2)
Finished
Return on
both sides
and top
9"
6" (15.2)
2 1/2" (6.4)
B
1-1/2" Landing / Finished Spacer
24" (61)
B
Cabinet
Hinge
Minimum Clearance Dimensions with Trims Installed
• 3/4" Landing needed for cabinetry door/drawer edge
adjacent with hinge opposite of cutout.
• 1-1/2" landing needed for cabinetry door/drawer edge
with hinge adjacent to cutout
Trim
0.75 min
Hinge Opposite
Cutout.
A. Option clearance
Cabinet Handle next to trim. 3/4" Minimum landing
clearance (Matching Cabinet Finish) needed from
cutout opening for Standard Trim.
B. Option clearance
Cabinet hinge next to trim. 1-1/2" Minimum landing
clearance (Matching Cabinet Finish) needed from
cutout opening for Standard Trim to clear cabinetry
door hinges.
8
8
A
¾" Landing/Finished Space
A
B
1.5 min
Hinge Adjacent
to Cutout.
A
Cabinet
Handle
31-1000731 Rev. 3