14 EN – Quick installation guide
Connect the external control cables to the control unit
See
Step-by-step drawings for an installation example of standard drive configuration in
Rittal VX25 800 mm wide enclosure
Step
Tasks
To connect the intermediate control cables between the control unit and the drive module to the
1
drive module, route the cables through the slot in the middle front cover of the drive module at the
front or left side. First, remove the plate which covers the slot. Then, install the rubber grommet
from the accessories box.
Then, connect the control cables to the drive module as follows:
1. Connect power supply cable to terminal X2.
EN
2. Connect the STO cable to the INU STO connector.
3. Connect the fiber optic cables to the QOIA V8, V13, V2 and V7 connectors.
DA
DE
ES
FI
FR
IT
NL
PL
PT
RU
SV
Note: ISU ext. 24VDC connector is for supplying external 24 V DC to the line-side converter
TR
control unit if needed. ISU panel connector is for connecting the control panel to the line-side
converter control unit if needed.
Disconnect the control panel cable from connector X13 on the control unit.
ZH
2
Loosen the mounting screws of the control panel holder and take the holder off.
3
Install the control cable grounding clamp plate to the control unit.
4
(Page 105).
INU STO
ISU ext. 24VDC
ISU
panel
QOIA
QOIA
ZBIB
INU STO
X7 (STO1)
X8 (STO2)
X2
X3
V2
V2
V7
V1
V8
V21
V13
V22