Replacing The Batteries; Base Station; Measuring Station - Hama Color EWS-1400 Mode D'emploi

Masquer les pouces Voir aussi pour Color EWS-1400:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Warning
• Only connect the product to a socket that has been approved
for the device. The electrical socket must always be easily
accessible.
• Disconnect the product from the network using the power
button – if this is not available, unplug the power cord from
the socket.
4. Getting Started
4.1. Insert batteries / connect power supply

Measuring station

• Remove the screen protector from the display.
• Open the battery compartment (29) and remove the contact
breaker.
• Then close the battery compartment cover.
Note
Before use, ensure you insert the batteries in the measuring
station first and then in the base station.

Base station

• Remove the screen protector from the display.
• Plug the power supply connection cable into the socket (23)
on the base station. Switch the base station on by plugging
the power supply unit into a power outlet approved for this
purpose. The socket must be close to the base station and easily
accessible.
• Alternatively, open the battery compartment (25)and remove the
contact breaker. Close the battery compartment cover (25).
Note
If the batteries are inserted correctly and you connect the power
supply unit to the station, the base station will automatically
switch to the external power supply.

4.2. Replacing the batteries

Note – Replacing the batteries
• Note that the stations have to be resynchronised each time
after you change the batteries in the measuring or base
station.
• To do this, remove the batteries from the other station and
then reinsert them, or change them as required.
Measuring station
• When the
symbol appears (next to the outdoor humidity
(16)), replace the 2 AAA batteries for the measuring station
with 2 new ones.
• Open the battery compartment (29), remove and properly
dispose of the depleted batteries, and insert two new AAA
batteries with the correct polarity. Then close the battery
compartment cover.
Base station
• When the
symbol appears (next to the outdoor humidity
(5)), replace the 2 AA batteries for the measuring station with
2 new ones.
• Open the battery compartment (25), remove and properly
dispose of the dead batteries and insert two new AA batteries
with the correct polarity. Then close the battery compartment
cover (25).
5. Installation
Note – Installation
• We recommend initially placing the base and measuring
stations in the intended locations without installing them and
making all the settings described in 6. Operation – to do.
• Only install the stations once the appropriate settings have
been made and a stable wireless connection is established.
Note
• The wireless transmission range between the measuring and
base stations is up to 50 m in open spaces.
• Before installation, ensure that wireless transmission will not
be disrupted by interference or obstacles like buildings, trees,
vehicles, high-voltage lines, etc.
• Before the final installation, ensure that there is sufficient
reception between the intended installation locations.
• When installing the measuring station, ensure that it is
protected from direct sunlight and rain.
• The international standard height for measuring air
temperature is 1.25 m (4 ft) above ground.
Warning
• Buy special or suitable installation material from a specialised
dealer for wall-mounting.
• Ensure that no faulty or damaged parts are installed.
• Never apply force during installation. This could damage
the product.
• Before installation, ensure that the chosen wall is suitable for
the weight to be mounted, and make sure that there are no
electrical wires, water, gas or other lines at the installation
site on the wall.
5.1. Base station
• Use the base to position the base station on a level surface.
• Alternatively, you can install the base station on a wall using the
opening (24) on the back.
5.2. Measuring station
• You can also position the measuring station on a level outdoor
surface.
• We recommend installing the measuring station securely on an
outdoor wall (28).
• Install an anchor, screw, nail, etc. in the wall of your choice.
3

Publicité

Table des Matières
loading

Table des Matières