Charging a Lithium Battery in Storage Mode
This function is useful when you desire to charge or discharge a battery, which will not be used immediately.
This programme is only to be used with following batteries: Li-poly of 3.85 V, Li-ion of 3.75 V and Li-Fe of
3.3 V. the battery will be discharged if the original state exceeds the storage voltage level.
Discharging a Lithium Battery
Voltage Balancing and Monitoring During the Discharging Process
During storage charging and discharging, the charger monitors the voltage of each cell. When it detects an
abnormal cell, the charger will display the error and stop the process. Press INC to display the damaged cell.
V. 02 – 04/08/2016
VLE8
This display shows the real-time discharging status. Press TYPE/STOP to
stop the discharging process.
The discharge current value on the left may not exceed 1.0 A; the value on
the right may not drop below the voltage recommended by the
manufacturer to avoid discharging. Hold START/ENTER pressed for
3 seconds to start the discharging process.
a. number of cells
b. elapsed time
c. discharging current
d. battery voltage
e. discharged capacity
The charger indicates that the voltage of one is too low.
The 4
th
cell was damaged. The value dropped to 0 if a disconnection has
occurred.
10