Télécharger Imprimer la page

SICK GTB6L Manuel D'utilisation page 14

Publicité

OPERATING INSTRUCTION
10
Technical specifications
Laser class
Maximum pulse power
Pulse duration
Wavelength
Sensing range
Sensing range max.
Light spot size / distance
Supply voltage U
B
Output current I
max.
Switching frequency
Response time
Enclosure rating
en
Protection class
Circuit protection
Ambient temperature, operation
1)
Object with 90% remission factor (complies with standard white according to DIN 5033)
2)
Limit values
Reverse polarity protected U
Residual ripple max. 5 V
As of U
> 24 V, a max. load current I
3)
B
4)
With light / dark ratio 1:1
5)
Signal transit time with resistive load
6)
A = U
-connections reverse polarity protected
B
C = Interference suppression
D = outputs overcurrent and short-circuit protected
7)
As of T
≥ 45 °C, a max. supply voltage U
a
8)
Warm-up time @ -20 °C: 3 seconds
14
O P E R A T I N G I N S T R U C T I O N | GTB6L
connections
B
ss
= 50 mA is permitted.
max.
= 24 V and a max. load current I
B
GTB6L
1
≤ 11.90 mW
2 µs
670 - 690 nm
30 ... 400 mm
10 ... 400 mm
0.4 mm / 150 mm
DC 10 ... 30 V
100 mA
3)
1,000 Hz
4)
0.625 ms
IP67
III
A, C, D
6)
-20 ... +50 °C
= 50 mA is permitted.
max.
1)
2)
5)
7)8)
8025391.1NSI/2024-05-24 | SICK
Subject to change without notice

Publicité

loading