Installation Instructions
PREPARING THE OPENING
The following MINIMUM clearance dimensions must be maintained.
If a 30" (762mm) clearance between the cooking surface and overhead combustible materials or metal
cabinets cannot be maintained, a minimum clearance of 24"(610mm) is required and the underside of the
cabinets above the cooktop must be protected with not less than 1/4-inch-thick flame-retardant
millboard covered with not less than No. 28 MSG sheet steel, 0.015-inch-thick stainless steel,
0.024-inch-thick aluminum, or 0.020-inch-thick copper.
One and one-half inches (1-1/2" /38mm) minimum vertical clearance between the cooktop bottom and any
combustible surfaces.
• To ensure accuracy, it is best to make a template when cutting the opening in the counter.
Make sure the wall coverings, countertop and cabinets around the cooktop can withstand heat (up
to 200°F/ 94°C ) generated by the cooktop.
Wall coverings, cabinets and countertop must withstand heat up to 200°F/ 94°C.
A
H
F
MAX.depth of unprotected overhead cabinets
A
MIN. clearance from countertop to unprotected overhead surface
B
MIN. height from countertop to nearest cabinet on either side of unit
C
Width of cutout
D
Depth of cutout
E
MIN. clearance from cutout to left or right side walls
F
G
MIN. from front edge of cutout and front edge of countertop
H
MIN. between cutout and the wall behind the cooktop
C
F
E
G
B
D
14
20-1/2"
23-1/4"
520mm
590mm
Cooktop
1-1/2 (38mm) Min.
Vertical Clearance
IKE6401BT
13" (330mm)
30" (762mm)
18" (458mm)
22-1/16" (560mm)
19-5/16" (490mm)
1-3/4" (44mm)
2-3/4" (70mm)
2" (50mm)
3-9/16
"
91mm