Occupation of the DIP-switches:
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the TS-8 starts running. During the Reset, the motors are
trimmed and the device is ready for use within approximately 20 seconds.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.
Stand Alone operation
In the Stand Alone mode, the TS-8 can be used without controller. You can do without a controller as the TS-
8 features a built-in microphone, which provides automatic sound control.
Disconnect the TS-8 from the controller and set all DIP-switches to Off.
Call up the internal program
In order to call up the internal program, set DIP-switches No. 9 and 10 to On.
Master/Slave-operation
Connect the master and slave-devices as desribed above and set the DIP-switches accordingly.
Please note: If you wish to change from one operating mode into another, you have to unplug the projector
from the mains and plug it again.
International
L
N
25/54