AXIS Q1961-XTE Explosion-Protected Thermal Camera
(防 防 防 爆 爆 爆 サ サ サ ー ー ー マ マ マ ル ル ル カ カ カ メ メ メ ラ ラ ラ )
Version history
Version
1.0
2.0
Specific conditions of use
WARNING
Always refer to the product certificates for any specific conditions of use.
•
Take precautions to minimise the risk of electrostatic charging. For more information,
see Maintenance on page 9 .
•
The equipment shall only be used in an area of at least pollution degree 2, as defined in
IEC 60664-1.
•
Equipment must not be exposed to impact energy exceeding 2 Joules to the window, and
4 Joules to the rest of the body.
•
Orientation of the product must be in accordance with the installation instructions. The
device must not be surrounded with more dust than the surfaces can retain.
•
Capacitance of accessible metal parts of the equipment is 85.4 pF and shall be considered
in the specific application.
Installation
WARNING
All installation and maintenance must be carried out by a suitably skilled electrician
in accordance with all local and national standards and codes of practice e.g. NFPA70
(National Electrical Code), CSA C22.1 (Canadian Electrical Code, Part I Safety Standard for
Electrical Installations), IEC/EN 60079-14 (Explosive atmospheres - Electrical installations
design, selection and erection) and IEC/EN 60079-17 (Explosive atmospheres. Electrical
installations inspection and maintenance).
•
The installer must comply with the technical data attached.
•
Ensure that all items are approved and certified for the environmental and installation
requirements. Check the rating label to ensure that the device is being used within
the correct ambient temperature and environmental conditions, and that the power
supply is suitable.
•
The device must be installed ≤2 000 m above sea level.
•
Cable entry points can reach a temperature of 81.1°C. Use a suitable cable for the end
application.
Date
2024-02-02
2024-06-03
6
Details
First release
Updated illustrations and
change of part number to
3086320 (old part number:
2566564)