PRIMING WITH MATERIAL
12 - Remove suction rod (L) and drain rod (O) from material container and immerse them in a solvent
filled container.
13 - Open drain valve (N), wait until the material flows out regularly, then shut off the drain valve (N).
14 - Point the spray gun towards the material container and trigger the gun until the material flows out
regularly.
WORK
12 - Remove suction rod (L) and drain rod (O) from material container and immerse them in a solvent
filled container.
13 - Open drain valve (N), wait until the material flows out regularly, then shut off the drain valve (N).
14 - Point the spray gun towards the material container and trigger the gun until the material flows out
regularly.
Nota : Some of these pumps are designed for AIRMIX ® spraying when using long hoses and medium or
high viscosity fluids.
For this use, a spraying air kit shall be mounted on the pump air supply in order to feed compressed air to
the spray gun.
2-2 PUMP SUPPLIED IN FILLING (CIRCULATING)
Interconnect the fluid inlet of the pump with the circulating supply hose and start up the pump as it is
specified previously.
If the pump is a FLOWMAX ® one :
WARNING:
Fluid section filling pressure :
WARNING : Do not create overpressure.
Never use the pump when an isolating gate on the supply circuit (upstream from the
FLOWMAX ® fluid section) is shut : it would damage the bellows.
Do not install a material regulator on the supply circuit or any arrangement that could
perform as a non-return valve.
SAMES KREMLIN
2 bar maximum / 29 psi maximum
- 4 -
N° : 578.029.120-UK-1810