CAUTION :
Before any action on the pump, shut off the compressed air supply and
depressurize the system.
The pump is manufactured under the ATEX agreement and can not be modified.
SAMES KREMLIN will not be held responsible for any failure to comply with that instruction.
FLUID MOTOR OR AIR MOTOR REPLACEMENT (REFER TO DOC. 573.407.050 &
573.410.050)
Guards (air motor cover, coupling shields, housings ...) have been designed for
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
To remove a component of the pump :
- Disassemble all the accessories of the pump (rods, filter), if it necessary.
- Put aside the pump, if it is necessary (the pump is fitted with an hoisting ring).
The fluid section of the pump consists of 2
sub-assemblies :
- the upper part (bellows suction
sub-assembly : A)
- the lower part (fluid sub-assembly :
B)
This sub-assembly is more frequently
service than the A sub-assembly.
SAMES KREMLIN
safe use of the equipment.
Before removing the B sub-assembly or the A
sub-assembly, you must remove the connecting
rod (41). For that :
- Unscrew the nut fitting (38) and the screws (43 &
45),
- Remove the connecting rod (41).
A
B
- 1 -
36
37
38
N° : 578.156.110-UK-2208
44
45
43
42
41