U L S A T I S F A C T I O N R A T I N G S L I S ‐
T E D
The total control output current and ambient temperature will be restricted as
follows depends on the number of the sensors.
1 control output setting
Stand-alone:
Input: 12 - 30 Vdc, Class 2, Max.
0.152 A
Output: 12 - 30 Vdc, Class 2, Max.
0.1 A
Maximum Ambient Temperature:
+55 °C
Base unit stand-alone use:
Input: 12 - 24 Vdc, Class 2, Max.
0.152 A
Output: 12 - 30 Vdc, Class 2, Max.
0.1 A
Maximum Ambient Temperature:
+55 °C
Up to 2 units:
Base unit
Input: 12 - 24 Vdc, Class 2, Max.
0.144 A
Output: 12 - 30 Vdc, Class 2, Max.
0.02 A
Expansion unit
Output: 12 - 30 Vdc, Class 2, Max.
0.02 A
Maximum Ambient Temperature:
+55 °C
Up to 5 units:
Base unit
Input: 12 - 24 Vdc, Class 2, Max.
0.36 A
Output: 12 - 30 Vdc, Class 2, Max.
0.02 A
Expansion unit
Output: 12 - 30 Vdc, Class 2, Max.
0.02 A
Maximum Ambient Temperature:
+50 °C
Up to 8 units:
Base unit
Input: 12 - 24 Vdc, Class 2, Max.
0.576 A
Output: 12 - 30 Vdc, Class 2, Max.
0.02 A
Expansion unit
Output: 12 - 30 Vdc, Class 2, Max.
0.02 A
Maximum Ambient Temperature:
+45 °C
Up to 16 units:
Base unit
Input: 12 - 24 Vdc, Class 2, Max.
1.152 A
Output: 12 - 30 Vdc, Class 2, Max.
0.02 A
Expansion unit
Output: 12 - 30 Vdc, Class 2, Max.
0.02 A
Maximum Ambient Temperature:
+40 °C
Environmental
Enclosure Tye Rating: Type 1
8027404.1N1K/2024-04-17/de, en, es, fr, it, pl, pt, ru
E300503
2 control outputs setting
Stand-alone:
Input: 12 - 30 Vdc, Class 2, Max.
0.152 A
Output: 12 - 30 Vdc, Class 2, Max.
0.05 A (each)
Maximum Ambient Temperature:
+55 °C
Base unit stand-alone use:
Input: 12 - 24 Vdc, Class 2, Max.
0.152 A
Output: 12 - 30 Vdc, Class 2, Max.
0.05 A (each)
Maximum Ambient Temperature:
+55 °C
Up to 2 units:
Base unit
Input: 12 - 24 Vdc, Class 2, Max.
0.144 A
Output: 12 - 30 Vdc, Class 2, Max.
0.01 A (each)
Expansion unit
Output: 12 - 30 Vdc, Class 2, Max.
0.01 A (each)
Maximum Ambient Temperature:
+55 °C
Up to 5 units:
Base unit
Input: 12 - 24 Vdc, Class 2, Max.
0.36 A
Output: 12 - 30 Vdc, Class 2, Max.
0.01 A (each)
Expansion unit
Output: 12 - 30 Vdc, Class 2, Max.
0.01 A (each)
Maximum Ambient Temperature:
+50 °C
Up to 8 units:
Base unit
Input: 12 - 24 Vdc, Class 2, Max.
0.576 A
Output: 12 - 30 Vdc, Class 2, Max.
0.01 A (each)
Expansion unit
Output: 12 - 30 Vdc, Class 2, Max.
0.01 A (each)
Maximum Ambient Temperature:
+45 °C
Up to 16 units:
Base unit
Input: 12 - 24 Vdc, Class 2, Max.
1.152 A
Output: 12 - 30 Vdc, Class 2, Max.
0.01 A (each)
Expansion unit
Output: 12 - 30 Vdc, Class 2, Max.
0.01 A (each)
Maximum Ambient Temperature:
+40 °C
d e
WLL80 | SICK
17