o After washing, dry and polish the unit with a soft, dry cloth.
o If the unit is used intensively, regularly remove deposits from the bottom of the water
container using a vinegar and water solution or commercially available descaler.
6.3 Safety instructions for maintenance
o Check the mains connection cable for damage from time to time. Never operate the
device when the cable is damaged. A damaged cable must immediately be replaced
by customer service or a qualified electrician to avoid dangers.
o In case of damage or malfunction, please contact your stockist or our customer
service centre. Pay attention to the troubleshooting tips in pt. 7.
o Only a qualified technician and using original spare parts and accessories should
carry out repairs and maintenance of the device. Do not attempt to repair the
device yourself.
7. Possible Malfunctions
PROBLEM
The unit does not work.
The red standby light and
green heating control light
do not come on.
The unit is on, the
temperature is set, but the
green heating light does not
come on and the unit is not
heating.
The unit is on, the
temperature is set, but the
unit does not reach the set
temperature.
CAUSE
Plug not connected
correctly
Fuse of mains opened
• The safety thermostat
has come on.
The thermostat is
damaged
SOLUTION
Connect plug correctly
Control fuse, test
machine on other plug
Reset the safety
thermostat 1)
Contact a sales agent
- 23 -