4.7. Electrical connection
1. Unscrew the screws 2 and 3 with a screwdriver.
2. Remove the cover plate 1.
Connection of Qube 9 kW and 10.5 kW
(QUBE-090 / QUBE-105)
1. Guide the connection cable through the
feed-through 4.
2. Connect the connectors of the connection
cable to the U – V – W – N – PE terminals
of the sauna heater and to the applicable
sauna control unit terminals. Observe the
installation instructions for the sauna control
unit when doing so.
3. Reattach the cover panel 1 to the heater.
p. 18/28
1
2
3
U
V
W
N
PE
4