Installation Instructions - Single Integrated Installation
STEP 5 CONNECT WATER SUPPLY
WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
WARNING
Attach tubing clamp using existing hole only. DO
NOT drill into the refrigerator.
House
Water Supply
Locate and bring the tubing to the front of the cabinet.
Turn the water on to flush debris from the line. Run
about a quart of water through the tubing into a
bucket, then shut off the water.
Remove strain relief screw to allow for enough slack
to make a proper water connection. (Screw must be
replaced in the next step.)
Strain Relief
Screw
Copper Tubing:
Slip a 1/4" nut and ferrule (provided) over both ends
of the copper tubing. Insert the tube into the union
fitting on the unit and tighten the nut to the union.
Turn on the water to check for leaks.
SmartConnect
Tubing:
NOTE: The only GE Appliances-approved plastic
tubing is supplied in the SmartConnect
Tubing kits. Do not use any other plastic water supply
line because the line is under pressure at all times.
Other types of plastic may crack or rupture with age
and cause water damage to your home.
Insert the molded end of the tubing into the
refrigerator or freezer connection. Tighten the
compression nut until it is just hand-tight.
Follow the instructions provided with the tubing.
Overtightening can cause leaks!
Turn on the water to check for leaks.
31-1000190 Rev. 3
ELECTRIC SHOCK HAZARD
Refrigerator/
Freezer
Freezer
Water Supply
Water Supply
Refrigerator
STEP 6 INSERTING/SECURING
INTO CABINET SURROUND
Plug unit into the outlet in the wall.
WARNING
To reduce the risk of electrical shock, be careful
during the remaining installation steps not to touch
wiring or electrical components inside the compressor
compartment while the appliance is plugged in and
the front access cover is not in place.
Find the installation
string that is attached
to the door of the unit;
this is to be used as
you are pushing the
unit back into the
opening. The string is
attached to the power
cord; as you walk the
unit back into the opening you should pull the string
tight to make sure the power cord is routed under-
neath the unit.
Slowly walk the unit into opening making sure not to
touch the cabinetry on the sides and top to prevent
damage. Door face should be 7/8" behind the front
face of surrounding cabinets on either a stainless or
custom panel installation.
WARNING
This appliance is top heavy, especially with the
door open, and must be secured to prevent tipping
forward which could result in death or serious injury.
Place power cord on its edge and pull under product
between rollers and away from the anti-tip bracket to
ensure cord is not damaged during installation.
String
As you walk the unit back into the opening, you
should pull the string tight to make sure the power
cord is routed underneath the unit.
Replace the
waterline strain
relief screw.
Store the
excess string
and water tubing
under the unit.
WARNING
Replace waterline strain relief in front rail location as
shown.
43
Electrical Shock Hazard.
Installation
String
Tip Over Hazard.
Power Cord
Strain Relief
Screw
Electrical Shock Hazard.

Publicité