Installation Instructions - Single Integrated Installation
STEP 2 INSTALL WATER LINE
(Cont.)
NOTE: Saddle type shut-off valves are included in
many water supply kits. Before purchasing, make sure
a saddle type valve complies with your local plumbing
codes.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle
valves are illegal and use is not permitted in
Massachusetts. Consult with your licensed plumber.
Route 1/4" OD copper or SmartConnect
(WX08X10006) plastic tubing between house cold
water line and the water connection location at the
front of the unit.
™
SmartConnect
Refrigerator
Tubing Kits are available.
One 8' (2.4m) water line
(WX08X10006) is needed for
each unit. The waterline will
be taped to the floor using
masking tape after anti-tip
bracket installation.
Tubing should be long enough to extend to the front
of the unit. Allow enough tubing to accommodate
bend leading into the water line connection. Unit
must be tipped on its side to route waterline
underneath and to the front of the appliance.
NOTE: The only GE Appliances approved plastic
tubing is supplied in the SmartConnect
Tubing kits. Do not use any other plastic water supply
line because the line is under pressure at all times.
Other types of plastic may crack or rupture with age
and cause water damage to your home.
STEP 3 PREPARING UNIT FOR
INSTALLATION
Place the unit in front of the installation opening in a
way that the unit is in front of the intended installed
location.
STEP 4 INSTALL ANTI-TIP BRACKET
™
™
Refrigerator
42
WARNING
This appliance is top heavy, especially with any
doors open, and must be secured to prevent tipping
forward which could result in death or serious injury.
Read and follow the entire installation instructions
for securing the appliance with the anti-tip system.
Remove the anti-tip bracket from the hardware kit.
Anti-tip bracket should be mounted against the back
wall or up to 25-1/2" (64.7 cm) maximum from front of
opening. Use floor mounting method if the bracket is
not against a wall (bracket hardware is provided for
mounting into wood, steel studs and concrete).
Unit
From Enclosure
18"
8-7/8"
(22.5 cm)
24"
5-3/4"
(14.6 cm)
30"
5-3/4"
(14.6 cm)
Measure and mark from the right side of the opening
per the table depending on the size of the unit you
are installing.
Mount the anti-tip bracket centered about the mark
and flush to the floor as shown. Mark 3 holes for wall
mounting or 4 holes for floor mounting.
WOOD MOUNTING: Predrill with 3/16" drill bit, 2"
deep, then install lag bolts with a 7/16" driver.
CONCRETE MOUNTING: Predrill with a 5/32"
concrete bit, 2" deep, then install tapcon screws with
a 7/16" driver.
STEEL MOUNTING: Predrill with a
1/2" drill bit, insert toggle, then install
bolts with a 7/16" driver.
The bracket must be screwed to
either the FLOOR or REAR WALL.
If the enclosure is deeper than 25
½", the anti-tip bracket should be
secured to the floor 25" from front of the enclosure.
Tape the waterline to the wall and floor approximately
3" to the left of the anti-tip bracket. Apply tape about
every 5" toward the front of the opening (tape will
prevent the unit from
rolling over the waterline
during installation). Do
not tape near the cabinet
front in order to keep tape
hidden under the unit.
Tip Over Hazard.
3"
5"
31-1000190 Rev. 3