Télécharger Imprimer la page

Monogram ZK1SN189NLH Instructions D'installation page 17

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions - Dual Integrated Installation
STEP 3 PREPARING UNIT FOR
INSTALLATION (Cont.)
#8 Hex
Screws
2 Pin
Connector
to Heater
Connector
Do NOT
Remove Wire
Standoff
Transformer
3 Pin
Connector
Master Switch
Enclosure assembly upper
is hidden for clarity.
STEP 4 INSTALL ANTI-TIP BRACKET
WARNING
These appliances are top heavy, especially with any
doors open, and must be secured to prevent tipping
forward which could result in death or serious injury.
Read and follow the entire installation instructions
for securing the appliance with the anti-tip system.
Remove the anti-tip bracket from the hardware kit.
Anti-tip bracket should be mounted against the back
wall or up to 25-1/2" (64.7 cm) maximum from front of
opening. Use floor mounting method if the bracket is
not against a wall (bracket hardware is provided for
mounting into wood, steel studs and concrete).
LH Unit
18"
24"
26-5/8"
23-1/2'
67.6 CM
59.6 CM
32-5/8"
29-1/2"
67.6 CM
59.7 CM
38-5/8"
35-1/2"
67.6 CM
59.7 CM
31-1000190 Rev. 3
Cover Top
Tip Over Hazard.
RH
UNIT
30"
23-1/2"
8-7/8"
18"
59.7 CM
22.5 CM
29-1/2"
5-3/4"
24
59.7 CM
22.5 CM
35-1/2"
5-3/4"
30
59.7 CM
22.5 CM
STEP 4 INSTALL ANTI-TIP BRACKET
(Cont.)
Measure and mark from the RH side of the opening
per the table above depending on the size of the RH
unit you are installing.
Measure and mark again from the RH side of
the opening per the table and depending on your
combination of LH and RH units.
For example, if installing an 18" LH unit and a 30" RH
unit, use 5-3/4" and 38-5/8".
Mount the anti-tip bracket centered about the marks
and flush to the floor as shown. Mark 3 holes for wall
mounting or 4 holes for floor mounting.
WOOD MOUNTING: Predrill with 3/16" drill bit, 2"
deep, then install lag bolts with a 7/16" driver.
CONCRETE MOUNTING: Predrill with a 5/32"
concrete bit, 2" deep, then install
tapcon screws with a 7/16" driver.
STEEL MOUNTING: Predrill with a
1/2" drill bit, insert toggle, then install
bolts with a 7/16" driver.
The bracket must be screwed to
either the FLOOR or REAR WALL.
If the enclosure is deeper than 25 ½", the anti-tip
bracket should be secured to the floor 25" from front
of the enclosure.
Tape the waterline to the wall and floor approximately
3" to the left of the anti-tip bracket. Apply tape about
every 5" toward the front of the opening (tape will
prevent the unit from rolling over the waterline during
installation). Do not tape near the cabinet front in
order to keep tape hidden under the unit.
3"
17
RH Unit
LH Unit
3"
5"
5"

Publicité

loading