Installation Instructions - Dual Retro-Fit Installation
STEP 2 INSTALL WATER LINE
(Cont.)
NOTE: Saddle type shut-off valves are included in
many water supply kits. Before purchasing, make sure
a saddle type valve complies with your local plumbing
codes.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle
valves are illegal and use is not permitted in
Massachusetts. Consult with your licensed plumber.
Connect the jumper water line from the ZKR42N or
ZKR48N Trim Retro Kit to the house cold water line.
Tighten the compression nut hand tight, then tighten
one additional turn with a wrench. Overtightening
can cause leaks!
Connect the other end of the jumper water line to the
water fitting tee supplied in the trim retro kit. Tighten
the compression nut hand tight, then tighten one
additional turn with a wrench. Overtightening can
cause leaks!
Water Fitting Tee
Route 1/4" OD copper or SmartConnect
(WX08X10006) plastic tubing between water fitting
tee and the water connection location at the front of
the unit.
SmartConnect
Refrigerator Tubing Kits are
available. One 8' (2.4m) water line (WX08X10006) is
needed for each unit.
Tubing should be long enough to extend to the front
of the unit. Allow enough tubing to accommodate
bend leading into the water line connection. Unit
must be tipped on its side to route waterline
underneath and to the front of the appliance.
NOTE: The only GE Appliances approved plastic
tubing is supplied in the SmartConnect
Tubing kits. Do not use any other plastic water supply
line because the line is under pressure at all times.
Other types of plastic may crack or rupture with age
and cause water damage to your home.
Tape the jumper waterline and water fitting tee to the
back wall. The waterlines will be taped to the floor
using masking tape after anti-tip bracket installation.
Water Line Jumper
Refrigerator
STEP 3 PREPARING UNIT FOR
INSTALLATION
Unpack the heater Unification Kit (ZKUN) and make
sure all of the components on the list are included.
NOTE: Ensure the heater connector cord is toward the
top of the unit when installed.
Place the right hand unit in front of the installation
opening in a way that the unit is in front of the
intended installed location.
Install adhesive heater on the outside of the unit to the
left side of the case. Install heater 4" below the case
top. Heater should be centered front to back on the
metal case.
4"
Adhesive
Heater
WARNING
Hazard.
To avoid the risk of electric shock, make
sure the power cord is not plugged into the wall outlet.
Install the transformer into the case top assembly:
1. Remove cover top by removing eight #8 hex screws
and keep aside for assembling back the cover top.
2. Place the transformer into the case top provided in
ZKUN kit and secure it with the existing (1/4") hex
screws to left front of case top.
3. Connect the 2 pin transformer connector to the
heater connector and 3 pin connector to panel
control, make sure locking tabs are engaged.
4. NOTE: Verify the master switch is on.
5. Assemble the cover top with screws save from
previous step.
28
Clips
Electrical Shock
31-1000190 Rev. 3