maintenance
cleaning
carbon filter
If you plan to use the appliance as a recirculation hood, you
must first install the carbon filter. You must then also set the
switch located at the back of the appliance to F. In the case
of normal use the carbon filter must be replaced twice
annually. In the case of intensive use the carbon filter should
be replaced more frequently.
installing / replacing
1
Remove the grease filters.
2
Remove the cover from the carbon filter housing.
A
3
Place the carbon filter in the carbon filter housing.
4
Secure the filter with locking pin A.
5
Reinstall the carbon filter cover.
6
If necessary set the switch in the appliance to position "F"
(filter mode) (see also "setting", below).
7
Reinstall the grease filters.
setting
Remove the filters from the extractor hood.
If you are going to use the appliance as a recirculation hood,
A
set the switch located inside the appliance at the back to
position F (filter mode) (the flap is closed). You must then
also install the carbon filter (see "carbon filter", above).
F
If you are connecting the hood to a flue, set the switch
located inside the appliance at the back to position A (the flap
is open).
GB 10
faults
what should I do if...
If the appliance does not work properly, this does not always mean that it is defective.
Try to deal with the problem yourself first. Phone the service department if the advice
given below does not work.
attention:
Disconnect the appliance from the mains before starting the repair, preferably by
removing the plug from the socket or setting the main switch to zero.
fault
cause
Lighting is not functioning.
Light bulb defective.
Halogen bulb defective.
attention:
Use only the same light
bulbs with the wattage
stated.
Extractor hood makes a
Discharge too long or too
noise.
many bends in the duct.
Motor defective.
No extraction.
Motor or controls defective.
Connection cable defective.
solution
Remove the grease filters.
This gives access to the
light bulbs. Unscrew the
bulb from the fitting and
replace it with a new 40 W
bulb.
Pull the inner ring
downwards with a
screwdriver (see
illustration).
Take care: The glass is
loose!
Pull the halogen bulb out
of the fitting and replace it
with a new 20 W halogen
bulb. Use a clean cloth to
hold the new bulb.
Change the discharge
ducting (see installation
guide).
Phone the service
department.
Phone the service
department.
Phone the service
department.
GB 11